The Waterpilot FMX11 transmitter is typically used in environmental applications for hydrostatic level measurement. It is certified for drinking water applications and can be used in wells, storage tanks, water towers, dams, gauging stations, lakes and rivers.
Temperature: –10 to +70°C (14 to 158°F)
Measuring range: 0 to 2bar / 20m H20 (0 to 30psi / 67ft H2O)
Cable length: 6 to 30m
Accuracy: up to ±0.35%
Drinking water approvals: ACS, KTW, NSF61, DVGW
Certifications: cULus
Measuring principle |
Hydrostatic pressure |
Characteristic |
Compact probe with metallic cell for hydrostatic level measurement |
Supply voltage |
8...28 VDC |
Reference Accuracy |
pn ≥ 400mbar: 0.35 % |
Long term stability |
0.1 % of URL/year |
Process temperature |
-10°C...+70°C |
Ambient temperature |
-10°C...+70°C |
Measuring cell |
200 mbar...2 bar |
Process connection |
Suspension clamp |
Material process membrane |
Metal |
Communication |
4...20 mA |
Drinking water approvals |
NSF, KTW, ACS |